API674 Discharge Dampener

API674 pump discharge pulsation dampeners are often a necessary accessory for multi-plunger high pressure reciprocating pumps, as such pumps can produce damaging levels of pulsation and vibration as each slug of liquid is discharged from the cylinder out through the discharge valve and into the pipework.

As the slug of liquid exits the pump cylinder it is will be pushed into a pipeline that is already full of liquid. If the liquid volume in the pipe cannot be fully compressed to make space for this new slug of liquid, or if the pipe containing the liquid will not stretch to give some additional volume, then the pressure in the liquid will rise and a pressure pulse will occur.

How high this pressure pulse goes will depend on how fast the slug of liquid is pushed out it into the pipeline, the compressibility of the liquid already in the pipeline and the stiffness of the pipe material.

The magnitude of the pressure pulses that are generated at the pump, and the forces that they impose on the piping system can be assessed using the guidance given in API674. This specification, produced by the American Petroleum Institute provides conservative guidance that enables the use of simulation analysis to design out these pulsation forces either through modification of the piping system, or by the installation of a pulsation dampener in the discharge pipework, usually positioned immediately downstream of the pump.

This discharge dampener may take one of several forms, however, whichever form is fitted they all have the same thing in common in that they introduce a calculated amount of elasticity into the piping system that will expand and/or contract as each new slug of liquid leaves the pump and enters the piping system, thereby allowing the system to accept each new slug of liquid with minimal pressure rise.